hwmon: (ina2xx) Use shunt voltage to calculate current
Since the shunt voltage and the current register report the same values when the chip is calibrated, we can calculate the current directly from the shunt voltage without relying on chip calibration. With this change, the current register is no longer accessed. Its register address is only used to indicate if reading or writing current or shunt voltage is desired when accessing registers. Reviewed-by: Tzung-Bi Shih <tzungbi@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
4d5c2d9867
commit
63fb21afc1
1 changed files with 13 additions and 1 deletions
|
@ -480,6 +480,8 @@ static int ina2xx_curr_read(struct device *dev, u32 attr, long *val)
|
|||
{
|
||||
struct ina2xx_data *data = dev_get_drvdata(dev);
|
||||
struct regmap *regmap = data->regmap;
|
||||
unsigned int regval;
|
||||
int ret;
|
||||
|
||||
/*
|
||||
* While the chips supported by this driver do not directly support
|
||||
|
@ -492,7 +494,17 @@ static int ina2xx_curr_read(struct device *dev, u32 attr, long *val)
|
|||
*/
|
||||
switch (attr) {
|
||||
case hwmon_curr_input:
|
||||
return ina2xx_read_init(dev, INA2XX_CURRENT, val);
|
||||
/*
|
||||
* Since the shunt voltage and the current register report the
|
||||
* same values when the chip is calibrated, we can calculate
|
||||
* the current directly from the shunt voltage without relying
|
||||
* on chip calibration.
|
||||
*/
|
||||
ret = regmap_read(regmap, INA2XX_SHUNT_VOLTAGE, ®val);
|
||||
if (ret)
|
||||
return ret;
|
||||
*val = ina2xx_get_value(data, INA2XX_CURRENT, regval);
|
||||
return 0;
|
||||